Description
•Shift Down/Minus
•Shift Left
•Shift Right
• Return
• Menu&ConfirmSetting Date and TimeWhen you connect DC power, in order to enter the main interface, you will first need to set the local timePress ENT to enter Setup MenuSet Date & Time by touch ” ↑” ” ↓ ” , when ” < " point to " set Date& Time " , press ENT confirm to enter settingsPress “→ “(shift right) OR ” ← “(shift left) to set the year, month and day.
Press “↑ “(+) OR ” ↓ “(-) to adjust the number.
Press ” ENT” to save the DATE and shift the clock setting window
Press “↑ “(+) OR ” ↓ “(-) to adjust the number.
Press ” ENT ” to save and return back to main interface.Adjust pump , Input liquid– On the main interface , press the “→ “OR ” ← ” then press and hold the “ENT” to turn on the manual mode.
Check that the pump is functioning properly using manual mode before using calibration mode.Flow rate calibration– On the main interface , press the “↑ ” OR ” ↓ ” to enter the Flow calibration mode.
-Press “→ “(shift right) OR ” ← “(shift left) to select 1/2/3/4
– Press”ENT”to Confirm.Calibration : Find a measuring cylinder ( larger than 100m )Put the pumpoutlet hose into cylinder , and put the inlet hose into liquid Press “↑ ” to start .
The number adds from 0 ,view the cylinder liquid . When number shows 100ML , press “↑ ” to stop . Save this numerical value .
Press “ENT ” to save and back to the ” Correct Pumps ” page .
HOW TO USE
The water quality should be tested at least every 2 weeks when using a titration pump.
The outlet for titrating KH should be regularly cleaned of crystallization.
Do not place the titration pump in a damp environment
Please keep the machine on a horizontal plane during use . This will increase precision.